Reichert Ocular Response Analyzer G3
Reichert

Reichert Ocular Response Analyzer G3

The Reichert Ocular Response Analyzer G3 goes beyond traditional IOP measurement to deliver Corneal Hysteresis (CH) and Corneal Compensated IOP (IOPcc) — biomechanical metrics that add critical context to glaucoma risk assessment and progression prediction. CH is a more powerful predictor of glaucoma progression than IOP or central corneal thickness alone, and IOPcc provides a pressure reading less influenced by individual corneal properties — reducing the up-to-17 mmHg variance that affects traditional tonometry in normal eyes. Non-contact, no topical anesthesia required, single-touch automated alignment, and a touchscreen interface make the ORA G3 a practical, delegable addition to any pretest workflow focused on glaucoma-aware care. CPT 92145 is established for Corneal Hysteresis measurement.

Request Pricing → Schedule a Demo →
Practice Fit

Where The ORA G3 Wins

If your practice wants more than corneal-thickness-adjusted IOP assumptions — the ORA G3 adds biomechanical context that helps distinguish between patients at different risk levels for glaucoma progression.

Best Fit

Glaucoma-focused optometry and ophthalmology practices, medically oriented comprehensive offices, and clinics that want more than corneal-thickness-adjusted IOP assumptions — particularly practices interested in delegable, non-contact biomechanical assessment.

Why This

Traditional tonometry gives you pressure. The ORA G3 adds biomechanical context — Corneal Hysteresis and IOPcc provide data that helps distinguish between patients at different risk levels for glaucoma progression, even when their IOP looks similar.

Practice Impact

More confident glaucoma risk stratification in pretest, a billable measurement (CPT 92145), and a non-contact workflow that requires no drops and cooperates well with patients who are difficult with contact tonometry — including pediatric populations (89.8% cooperation vs 78.7% for Goldmann).

Platform Strengths

Why Practices Choose ORA G3

More Than Pressure Alone

Corneal Hysteresis measures the cornea's biomechanical dampening ability — a property that research shows is a stronger predictor of glaucoma progression than IOP or CCT alone. IOPcc provides pressure readings less influenced by individual corneal properties.

Practical Pretest Workflow

Non-contact, no drops, single-touch automated alignment on an intuitive touchscreen. No chinrest needed. Higher pediatric cooperation than Goldmann applanation. Easily delegated to trained technicians.

Billable Biomechanical Assessment

CPT 92145 is established for Corneal Hysteresis measurement, giving practices a reimbursable diagnostic that adds clinical value to their glaucoma workup without adding complexity to the workflow.

Image Quality

Clinical Imaging Examples

Device and interface images from the Reichert Ocular Response Analyzer G3 — Corneal Hysteresis, IOPcc, and waveform analysis for biomechanical glaucoma assessment.

Reichert ORA G3 ocular response analyzer device

ORA G3 System — Non-contact ocular response analysis with touchscreen interface

Reichert ORA G3 touchscreen showing corneal hysteresis measurement

Corneal Hysteresis Display — CH, IOPcc, and waveform data on intuitive touchscreen

Reichert ORA G3 in clinical pretest setting

Pretest Integration — Automated non-contact measurement in a delegable workflow

Product images courtesy of Reichert.

Specifications

Technical Details

Measurement Parameters
Corneal Hysteresis (CH), IOPcc, IOPg, Waveform Score
Measurement Range
7–60 mmHg (ISO 8612)
Method
Non-contact, patented automatic non-linear pressure ramp
Interface
Touchscreen, no chinrest
Communication
RS-232, EMR via ReichertCapture
Billing Code
CPT 92145
Dimensions
26.7(W) × 50.2(H) × 35.6(D) cm (10.5″ × 19.75″ × 14″)
Weight
10.4 kg (23 lbs)
Power
100/240 VAC, 50/60 Hz
Manufacturing
Designed and assembled in USA (Buffalo, NY)
The Carolina Optics Advantage

Why buy through us?

On-Site Installation & Training

We handle delivery, setup, calibration, and hands-on staff training so your team is capturing diagnostic-quality data from day one.

Glaucoma Program Consulting

We help you build a glaucoma assessment workflow that maximizes biomechanical data capture — from instrument configuration to staff training and billing strategy for CPT 92145.

Same-Day Support

When you need help, you get our team directly — no call center, no ticket queue. Most issues resolved within 24 hours.

Ready to see the ORA G3 in action?

Talk to our team about pricing, configuration options, and scheduling a hands-on demo at your practice.

Request Pricing → Schedule a Demo →